SG Series UPS by GE
Designed to provide high efficiency at partial load conditions, the GE SG Series UPS (Uninterruptible Power Supply) delivers low input harmonic distortion, and it has dynamic response and output voltage-regulation that are best-in-class. Reliable, efficient, and boasting up to 99 percent operating efficiency—with written guarantees thereto—a typical 5MW datacenter could conceivably realize savings up to $300,000 thanks to power & cooling efficiencies. Can be paralleled up to six modules. GE SG Series UPS come in the following sizes. 10KVA, 20KVA, 30KVA, 40KVA, 50KVA, 60KVA, 80KVA, 100KVA, 150KVA, 160KVA, 200KVA, 225KVA, 300KVA, 400KVA, 500KVA, 750KVA, 1000KVA, 1500KVA.
Features & Benefits Of GE SG Series UPS
- Redundant parallel architecture for ultimate reliability
- Up to 99% operating efficiency—with written efficiency guarantees thereto
- Proprietary eBoost technology minimizes efficiency losses
- Line conditioning & voltage regulation via patented design bypass inductor
- Proprietary technology to lengthen battery life
- Top or bottom cable access
- Matching battery and maintenance bypass cabinet for easy configuration
- Full front-maintainability design
- Scalable to meet future growth needs
- Can be paralleled up to six modules
GE SG Series 10-150 kVA high efficiency UPS Systems | |||||||||
---|---|---|---|---|---|---|---|---|---|
TOPOLOGY | True on-line, double conversion (VFI) with integral static switch and internal maintenance bypass | ||||||||
TECHNOLOGY | Advanced IGBT with SVM strategy, microprocessor controlled at optimal switching frequency | ||||||||
OPERATING MODES | True on-line double conversion, automatic bypass, frequency converter, RPA™ up to eight (8) units | ||||||||
OUTPUT POWER RATING kVA | 10* | 20* | 30 | 40 | 50 | 80 | 100 | 120 | 150 |
Output Power Factor | .8 | ||||||||
Output Power Rating (kW) | 8 | 16 | 24 | 32 | 40 | 64 | 80 | 96 | 120 |
Dimensions W x D x H (inches) | 27 x 32 x 71 | 32 x 32 x 71 | 47 x 32 x 71 | ||||||
Weight w/o Batteries (lbs) | 735 | 736 | 970 | 1147 | 1257 | 1489 | 1929 | 2006 | 2160 |
Noise Level dB(A) | 60 | 63 | 65 | ||||||
Input Voltage (VAC) | 480V, 3 Phase, 4 Wire w/ground (grounded WYE) | ||||||||
Input Voltage Range | -20% to +15% (without battery discharge) | ||||||||
Input Frequency | 60Hz +/-10% | ||||||||
Input Power Factor | .8 PF (.93 with input filter) (.93 with 5th filter) | ||||||||
Output Voltage (sinusoidal) (VAC) | 480V, 3 Phase, 4 Wire w/ground | ||||||||
Output Frequency | 60Hz +/-10% | ||||||||
Output THD at Linear Load | <2% | ||||||||
Output THD at Non-linear Load | <3% | ||||||||
Crest Factor | 3:1 | ||||||||
Overload Capability on Inverter | 125% @ 10 min., 150% @ 1 min. | ||||||||
Overload Capability on Automatic Bypass | 200% @ 5 min., 110% continuously | ||||||||
OUTPUT VOLTAGE REGULATION | |||||||||
Static | +/- 1% | ||||||||
0-100% Step Load | +/- 3% | ||||||||
SYSTEM EFFICIENCY | |||||||||
100% Load | 90.0 | 89.0 | 91.0 | 91.0 | 91.8 | 92.0 | 92.4 | 92.7 | 92.8 |
50% Load | 89.5 | 88.7 | 90.5 | 90.5 | 92.2 | 92.5 | 92.9 | 93.1 | 93.3 |
Ambient Operating Temp. | 32°-104°F (0°- 40°C) | ||||||||
Color | RAL 9003 (white) | ||||||||
Classifications and Listing | UL 1778 / IP20 / NEMA-PE-1 / ISO9001 | ||||||||
RFI and Surge Protection | EN 50091-2 / IEC 62040-2 / IEEE 587 B / FCC Class A compliance ** | ||||||||
Standard Connectivity | RS-232; programmable alarm contacts; programmable relays, SNMP (optional) | ||||||||
Warranty | Twelve (12) months after commissioning or eighteen (18) months after shipment, whichever occurs first *** |
GE SG Series 225-300 kVA high efficiency UPS Systems | |||||||||
---|---|---|---|---|---|---|---|---|---|
TOPOLOGY | True on-line, double conversion (VFI) with integral static switch and internal maintenance bypass | ||||||||
TECHNOLOGY | Advanced IGBT with SVM strategy, microprocessor controlled at optimal switching frequency | ||||||||
OPERATING MODES | True on-line double conversion, automatic bypass, frequency converter, RPA™ up to eight (8) units | ||||||||
OUTPUT POWER RATING kVA | 225 | 300 | |||||||
Output Power Factor | .8 | ||||||||
Output Power Rating (kW) | 180 | 240 | |||||||
Dimensions W x D x H (inches) | 65 x 32 x 71 | ||||||||
Weight w/o Batteries (lbs) | 2756 | 3087 | |||||||
Noise Level dB(A) | 67 | ||||||||
Input Voltage (VAC) | 480V, 3 Phase, 4 Wire w/ground (grounded WYE) | ||||||||
Input Voltage Range | -20% to +15% (without battery discharge) | ||||||||
Input Frequency | 60Hz +/-10% | ||||||||
Input Power Factor | .8 PF (.93 with input filter) | ||||||||
Output Voltage (sinusoidal) (VAC) | 480V, 3 Phase, 4 Wire w/ground | ||||||||
Output Frequency | 60Hz +/-10% | ||||||||
Output THD at Linear Load | <2% | ||||||||
Output THD at Non-linear Load | <3% (IEC 62040) | ||||||||
Crest Factor | >3:1 | ||||||||
Overload Capability on Inverter | 125% @ 10 min., 150% @ 1 min. | ||||||||
Overload Capability on Automatic Bypass | 200% @ 5 min., 110% continuously | ||||||||
OUTPUT VOLTAGE REGULATION | |||||||||
Static | +/- 1% | ||||||||
0-100% Step Load | +/- 3% | ||||||||
SYSTEM EFFICIENCY | |||||||||
100% Load | 92.4 | 92.7 | |||||||
50% Load | 92.7 | 93.1 | |||||||
Ambient Operating Temp. | 32°-104°F (0°- 40°C) | ||||||||
Color | RAL 9003 (white) | ||||||||
Classifications and Listing | UL 1778 / IP20 / NEMA-PE-1 / ISO9001 | ||||||||
RFI and Surge Protection | EN 50091-2 / IEC 62040-2 / IEEE 587 B / FCC Class A compliance * | ||||||||
Standard Connectivity | RS-232; programmable alarm contacts; programmable relays, SNMP (optional) | ||||||||
Warranty | Twelve (12) months after commissioning or eighteen (18) months after shipment, whichever occurs first ** |
GE SG Series 400-500 kVA high efficiency UPS Systems | |||||||||
---|---|---|---|---|---|---|---|---|---|
TOPOLOGY | True on-line, double conversion (VFI) with integral static switch and internal maintenance bypass | ||||||||
TECHNOLOGY | Advanced IGBT with SVM strategy, microprocessor controlled at optimal switching frequency | ||||||||
OPERATING MODES | True on-line double conversion, automatic bypass, frequency converter, RPA™ up to eight (8) units | ||||||||
OUTPUT POWER RATING kVA | 400 | 500 | |||||||
Output Power Factor | .8 | .9 | |||||||
Output Power Rating (kW) | 320 | 450 | |||||||
Dimensions W x D x H (inches) | 81 x 33 x 77 | 81 x 33 x 77 | |||||||
Weight w/o Batteries (lbs) | 4600 | 5100 | |||||||
Noise Level dB(A) | 65 | ||||||||
Input Voltage (VAC) | 480V, 3 Phase, 4 Wire w/ground (grounded WYE) | ||||||||
Input Voltage Range | -20% to +15% (without battery discharge) | ||||||||
Input Frequency | 60Hz +/-10% | ||||||||
Input Power Factor | .8 PF (.93 with input filter) | ||||||||
Output Voltage (sinusoidal) (VAC) | 480V, 3 Phase, 4 Wire w/ground | ||||||||
Output Frequency | 60Hz +/-10% | ||||||||
Output THD at Linear Load | <2% | ||||||||
Output THD at Non-linear Load | <3% (IEC 62040) | ||||||||
Crest Factor | 3:1 | ||||||||
Overload Capability on Inverter | 125% @ 10 min., 150% @ 1 min. | ||||||||
Overload Capability on Automatic Bypass | 200% @ 5 min., 110% continuously | ||||||||
OUTPUT VOLTAGE REGULATION | |||||||||
Static | +/- 1% | ||||||||
0-100% Step Load | +/- 3% | ||||||||
FAULT CLEARING CAPABILITY | |||||||||
Inverter | – | 220% for 100 msec. / 700% for 1.2 msec | |||||||
Static Bypass | – | 100 KAIC | |||||||
SYSTEM EFFICIENCY | |||||||||
100% Load | 94.0 | 93.8 | |||||||
50% Load | 94.2 | 94.4 | |||||||
Ambient Operating Temp. | 32°-104°F (0°- 40°C) | ||||||||
Color | RAL 9003 (white) | ||||||||
Classifications and Listing | UL 1778 / IP20 / NEMA-PE-1 / ISO9001 | ||||||||
RFI and Surge Protection | EN 50091-2 / IEC 62040-2 / IEEE 587 B / FCC Class A compliance | ||||||||
Standard Connectivity | RS-232; programmable alarm contacts; programmable relays, SNMP (optional) | ||||||||
Warranty | Twelve (12) months after commissioning or eighteen (18) months after shipment, whichever occurs first * |
GE SG Series 750 kVA high efficiency UPS System | ||||
---|---|---|---|---|
RECTIFIER CONFIGURATION | 6-PULSE (5TH FILTER) | 6-PULSE (5TH & 11TH FILTER) | 12-PULSE (W/O FILTER) | 12-PULSE (11TH FILTER) |
POWER RATING | ||||
Output Capacity | 750kVA / 675kW | |||
POWER FACTOR | ||||
Output Power Factor | 0.9 | |||
ENERGY EFFICIENCY | ||||
-50% Load | 94.2% | 94.1% | 92.1% | 92.0% |
-100% Load | 93.5% | 93.4% | 91.8% | 91.7% |
Heat Rejection (btu/hr) | 161,435 | 162,897 | 207,100 | 208,634 |
PHYSICAL | ||||
Weight w/o batteries (lbs / kg) | 9,557 / 4,335 | 9,696 / 4,398 | 11,091 / 5,031 | 11,230 / 5,094 |
Dimensions ( WxDxH) inches (mm) | 146.5 x 35.4 x 76.7 (3,720 x 900 x 1,950) inverter & rectifier cabinets | |||
INPUT | ||||
Input Voltage | 480 V, 3-phase, 4-wire w/ground (3-wire available) | |||
Voltage Range | -15% to +10% (w/o battery discharge) | |||
Frequency | 60 Hz +/- 5% | |||
Input THD | <7% | <5% | <9% | <4% |
Input Power Factor | 0.93 lagging | 0.96 lagging | 0.82 lagging | 0.86 lagging |
OUTPUT | ||||
Output Voltage | 480 V, 3-phase, 4-wire w/ground | |||
Frequency | 60 Hz +/- 0.01% free running — 60 Hz +/- 4% synchronized with utility | |||
Crest Factor | 3:1 | |||
Voltage Regulation | ||||
Static | +/- 1% | |||
100% Step Load | +/- 3% | |||
Voltage Distortion | ||||
100% Linear Load | 2% THD maximum | |||
100% Non-Linear Load | 3% THD maximum | |||
Overload Capability | ||||
Inverter | 125% for 10 minutes; 150% for 30 seconds | |||
Bypass | 110% continuous; 200% for 5 minutes | |||
BATTERY | ||||
Compatibility | VRLA or Wet cell | |||
Float Voltage | 545 VDC @ 68° F (20° C) | |||
Recharge Time | 10x discharge time (for battery runtime = 30 minutes) | |||
GENERAL | ||||
Audible Noise | 75 db(A) at 5 feet | |||
Operating Temperature | UPS: 32° to 104° F (0° – 40° C); Battery: 68° to 77° F (20° – 25° C) | |||
Humidity | 0-95%; non-condensing | |||
Safety Classifications & Listings | UL 1778 / IEC62040 / ISO 9001 | |||
Enclosure | IP20 and NEMA-PE-1 | |||
Communication / Connectivity | RS-232; programmable alarm contacts; programmable relays; SNMP (optional) | |||
Color | White (RAL 9003) | |||
Warranty | 12 months from start-up |
Industries & Applications
Designed for electrical engineering infrastructure in corporate, healthcare, banking, and industrial applications, the SG Series is particularly suited to:
- Smaller data centers
- Smaller telecom
- Hospitals, clinics, and medical centers
- Financial Institutions