GT Series UPS by GE

Easy to install and maintain, the transformerless GE GT Series UPS is a true voltage & frequency independent, online, double-conversion UPS designed to provide robust power protection for a wide range applications. Both its power and redundancy are expandable by adding units (N2) to create a parallel system. Available in tower or rack configurations. Standard features include standard remote monitoring, simplifying operation from remote or unmanned sites, as well as an RS-232 port and contact interface. Options include a Web-enabled SNMP card.


Features & Benefits Of GT Series

  • Fully-digitized microprocessor control for reliable performance
  • At-a-glance LED display of system status
  • Programmable outlet allows selective shutdown for lower priority loads
  • Quiet operation is ideal for office and medical environments
  • Advanced battery protection
  • Cold start capability
  • Hot swappable batteries
  • Multiple PDU options

Request a quote

 

Product Specifications

GT Series UPS – UL Listed (3kVA)
Single Phase Output Voltage 110V with 208V optional on 3kVA units
Wide input voltage window 80-138V Minimizes battery use, prolongs battery life
Pulse Width Modulation technology Eliminates the need to oversize the UPS
Internal automatic bypass switch Continuous power supply to the load even if the UPS is overloaded
Low input distortion Prevents disturbance to nearby electrical equipment
GT Series UPS – UL Listed (5-10kVA)
Single Phase Output Voltages 120/208V
Wide input voltage window 80-138V Minimizes battery use, prolongs battery life
Redundant and paralleling capability UPS capacity can be increased as site requirements require at no extra cost
Internal automatic bypass switch Continuous power supply to the load even if the UPS is overloaded
No load shutdown Prevents deep battery discharge al low loads
Frequency conversion 60/50Hz Automatic frequency detection

 

Technical Specs (3kVA)

GT Series UPS Technical Specification (3kVA)
MODEL NUMBER GT3000R , GT3000T208
RATING (VA/W) 3000 / 2400 , 3000 / 2400
BATTERY (V/Ah) 2000VA/1200W , 3000VA/1800W
BACKUP TIME @50% LOAD (25°C) 14 min.
OPTION FOR ADDITIONAL BATTERIES Yes
DIMENSIONS (HxWxD) 13.2×43.9×50.3cm (5.2×17.3×19.8in) , 37.3x14x42.4cm (14.7×5.5×16.7in)
NET WGT INCL. BATTERIES (kg / lbs) 34 / 74.9 , 30 / 66
INPUT VOLTAGE @ 100% LOAD (VAC) 80-138 , 160-275
INPUT FREQUENCY (Hz)* 50/60
OUTPUT VOLTAGE 100/110 , 160/208
NUMBER OF OUTLETS (4)NEMA 5-15R , (4)NEMA 6-20R
(1)NEMA L5-20R , (1)NEMA L6-20R
(1)NEMA L5-30R
SNMP COMPATIBILITY Yes
CORE VOLTAGE 120
PWM (PULSE WIDTH MODULATION) Yes
MAINTENANCE BYPASS Yes
INTERNAL BATTERIES Yes
INPUT PERFORMANCE RANGE Voltage (-33 to +17%); Frequency (55 to 65 Hz)
OUTPUT PERFORMANCE
OUTPUT THD LOAD Non-Linear (<6%); Linear (<3%)
VOLTAGE REGULATION LOAD Static (2%); 0-100% Step (8%)
OVERLOAD CAPABILITY 150% for 30 seconds
EFFICIENCY >87%
COMMUNICATIONS INTERFACE RS-232, Plug and Play, open collector alarm contacts
COLOR Front bezel: Aluminum Grey (RAL9006); Cabinet: White (RAL9010)
OPERATING TEMPERATURE 32° F – 104° F (0° C – 40° C)
RELATIVE HUMIDITY 95% non-condensing
AUDIBLE NOISE AT 3.3FT (1 METER) 47 dBA , 42 dBA
SAFETY UL 1778, CSA22.2-107, IEEE 62.41 CAT. A Lightning Safety
EMC FCC Class B (1kVA), FCC Class A (remaining), CISPR PUB. 22 Class A
ENCLOSURE NEMA1

GT Series UPS Technical Specification (5-10kVA)
MODEL NUMBER GT5000 RT GT6000 RT GT8000 RT GT10000 RT
RATINGS :
Power Rating Depending on Input Voltage VA/W VA/W VA/W VA/W
100V / 200V 4000 / 3400 4800 / 3400 6400 / 6400 8000 / 6400
110V / 220V 4500 / 3800 5400 / 3800 7200 / 7200 9000 / 7200
115V / 230V 5000 / 4000 60000 / 4200 8000 / 6900 8700 / 8000
120V / 208V 4800 / 4200 5200 / 4200 8000 / 6900 8700 / 8000
120V / 240V 5000 / 4200 6000 / 4200 8000 / 8000 10000 / 8000
127V / 220V 4800 / 4200 5200 / 4200 8000 / 6900 8700 / 8000
Input Thermal Circuit Breaker (A) 30 60
Internal Input Fuse 250V, Slow (A) Qty 30 30/2
INPUT CONVERTER :
AC Input Voltage Nominal:120/208V
AC Input Voltage Range 100/(173-200), 110/(190-220), 115/(198-230), 120/(208-240), 127/(220) V
Input Current Waveform Sine Wave
Input Current (A) at Nominal Input Voltage 20 40
Input Power Factor >0.97
Input Frequency Range 40 – 70 Hz
Input phase (L1 to L2) 120° / 180° / 240° ±10°
Inrush Current 40
OUTPUT CONVERTER :
AC Output Voltage 100 / 110 / 115 / 120 / 127 V (selectable)
AC Output Voltage Tolerance L-N ± 3%; L1-L2 ± 5% L-N ± 2%; L1-L2 ± 5%
Output Frequency 50 / 60 Hz, auto selection
Output Frequency Range nominal ± 5% with mains synchronizing
Output Waveform Sine wave
Harmonic Distortion < 3% with linear load, < 5% with non-linear full load
Power Factor at Nominal Input Voltage 0.87 0.8 0.86 0.92
Crest Factor (Peak to RMS Current) ≤ 3 : 1
Capacity Appliance Outlets with 55A Terminal Block
BYPASS :
AC Input Voltage Range ± 15% of selected output voltage
Frequency Tracking Rate 1Hz/s
Frequency Tracking Range ± 5% of selected frequency
Typical Transfer Time, msec 0
OVERLOAD CAPABILITY :
Overload Behavior During Battery Operation 130% for 10 seconds
200% for 2 seconds
130% for 1 minute
200% for 5 seconds
Overload Behavior During Bypass Operation Depends on rating of thermal circuit breaker (TCB)
125% of TCB value for 200 seconds
200% of TCB value for 10 seconds
300% of TCB value for 4 seconds
Overload protection
110% of TCB value for 300 seconds
130% of TCB value for 30 seconds
200% of TCB value for 5 seconds
BATTERIES (RATINGS GIVEN FOR 25º C) :
Nominal Voltage(Vdc) 144 288
Qty / Ah (In Battery Kit & Battery Ext. Pack) 12 pcs / 8Ah 24 / 8Ah
Type REW45-12 FR
Recharge Current 1A
Battery Recharge Time (Batt. Discharged at 100% Load) 6 hours for 90% capacity 3 hours for 90% capacity
GENERAL :
Weight UPS 30.3 Kg (67 lbs) 49.3 Kg (109 lbs)
Dimensions UPS (HxWxD) 176x430x592 mm (6.9×16.9×22.55 in) 267x430x660 mm (10.5×16.9×26 in)
Weight Battery Pack 43 Kg (94.7 lbs) 91 Kg (200.4 lbs)
Dimensions Battery Pack 87x430x592 mm (3.47×16.9×2255 in) 173x430x660 mm (6.8×16.9×26 in)
Enclosure / Protection steel-plastic / IP20
Mounting Rackmount or Tower mount with same unit
ENVIROMENT :
Safety Compliance UL 1778
Electromagnetic Compatibility EMI: FCC CFR47 Part 15, class A, ESD:
IEC61000-4-2, level 4
RS: IEC61000-4-3, level 3, EFT: IEC61000-4-4,
level 4, Surge: IEC61000-4-5, level 3
ANSI C62.41 (IEEE587) Category A
(level 3) & B (level 1)
Ambient Temperature 0 to +40ºC
Audible Noise at 3.3 ft. <55 dB(A), load and temperature dependent
Max. Relative Humidity 90% (non-condensing)
Color Black – RAL 9005

1. Due to continuous product improvements, program specifications are subject to change without notice.

 

Industries & Applications

The VH Series UPS is a more powerful solution in a compact footprint for smaller users who have relatively denser power requirements in clinics & hospitals, financial institutions, businesses, and other sites in need of an emergency power supply system. Available in rack or tower platforms and perfect for applications including but not limited to:

  • Smaller data centers, IT systems, or telecom closets with relatively larger power needs
  • Network switching & processing equipment
  • PLC controls
  • High-quality power backup system for AS-400 systems

Request a quote